Located in Hangzhou Donghu High-Tech Biomedicine Industrial Park, Hangzhou Aichong Biotech Co., Ltd. has been focusing on the R&D, production...
Product
Canine Distemper Virus (CDV) Antigen Rapid Test Kit is a chromatographic immunoassay for the qualitative detection of Canine Distemper Virus antigen in canine ocular nasal secretion. The invisible anti-CDV antibody(T line) and secondary antibody
Canine Distemper Virus (CDV) Antigen Rapid Test Kit is a chromatographic immunoassay for the qualitative detection of Canine Distemper Virus antigen in canine ocular nasal secretion. The invisible anti-CDV antibody(T line) and secondary antibody (C line) are immobilized on a nitrocellulose membrane in result window.Another
anti-CDV antibody is conjugated with colloidal gold particle and
immobilized on glass fiber as conjugate pad.When specimen
is applied into the sample well on device,CDV antigen will bind to the
gold conjugate and migrate on the surface of test strip by
passive diffusion,and a visible T line will appear in result window
after 10 minutes.The C line has to appear every time when the test has performed which indicates the test is performing properly.
1.Test Devices: 10 pieces test devices individually pouched.
2. Assay diluent in tube:10 units
3. Disposable swab:10 pcs
4. Disposable dropper cap:10 units
5. Work station:1 unit
6. Instructions For Use: 1 copy attached.
1. The test device,specimen,assay diluent should be brought to room temperature (15~30°C) prior to use.
2. Place the assay diluent tube on the work station and tear the aluminum film.
3. Collect specimen from eye conjunctiva or nasal discharge using a swab and insert the swab into the assay diluent tube immediatey.
4. Mix the swab until the specimen has been dissolved totally into the assay diluent (Approximately 10sec), then squeeze the solution
from the cotton swab as much as possible.
5. Discard the swab and cover the tube with dropper cap, then wait for 2 minutes.
6. Remove the test device from the foil pouch, and place it on a flat and dry surface.
7. Add 3 drops of assay diluent into the sample well on device, drop by drop vertically, and start the timer.
8. Read the results at 10~15 minutes, and the results after 15 minutes are no longer valid.
![]() | Positive result: Test line (T) and control line (C) within the result window indicate the presence of CDV antigen. Negative result: Only control (C) line appears in the result window indicating that CDV antigen has not been detected. Invalid result: If the control (C) line does not appear, the result might be considered invalid. The specimen should be retested. |